Schluter Ditra-Heat-E-R Non-Programmable Digital Thermostat with Indicator Light and a Floor Sensor – Ideal for Bathrooms and Kitchens – Simple On/Off Switch, Supports 120V/240V Cables – DHERT103/BW
$174.04
Product Description
Elevate Comfort with Heated Floors Thermostat
Customizable, easy-to-install floor warming accessories for any room
Schlute Non-Programmable Digital Thermostat for the DITRA-HEAT System
DITRA-HEAT-E-R is a non-programmable digital thermostat used to control the DITRA-HEAT-E-HK heating cables (either 120 V or 240 V).The thermostat features a built in Class A ground fault circuit interrupter (GFCI) with indicator light and includes a floor temperature sensor. DITRA-HEAT-E-R is operated via a simple on/off switch. Two heating cables may be connected to the thermostat, up to the total heating load limit of 15 amps. The DITRA-HEAT-E-RR power module may be used in conjunction with the thermostat when the heating load exceeds 15 amps (e.g., in large floor applications) to maintain a single point of control.
How to Install Your Ditra Thermostat
Please refer to the Quick Guide and Schluter-DITRA-HEAT Installation Handbook for complete DITRA-HEAT system installation instructions.
1. DITRA-HEAT-E-R must be installed in an electrical box. A single gang, deep electrical box or a double gang electrical box with a single gang mud ring is recommended to provide room for the wiring. The power supply must be shut off and all electrical connections must be made by a qualified electrician, according to the electrical and building codes effective in your region.
2. Connect the heating cable ground braid to the ground wire from the electrical panel. Remove the faceplate from the thermostat power base by loosening the screw and tilting the thermostat upward. Remove the back cover clip as well.
3. For ease of installation, form the electrical line wires into an “M” or accordion shape. This will make it easier to fold them neatly into the electrical box. Loosen the load screws at the top of the thermostat until they stop. Insert the heating cable conductors into the load terminals from the bottom. Since there is no polarity, either heating cable conductor can be connected to either load terminal. Secure the conductors by tightening the screws.
4. Insert the electrical line wires into the line terminals from the top. Refer to the back of thermostat for proper wiring configuration. Secure the wires by tightening the screws and fold the wires into the electrical box. Align and secure the thermostat power base to the electrical box. Thread the floor temperature sensors through the opening at the bottom right of the thermostat power base. Tape up the secondary floor temperature sensor and secure to the power base.
5. Strip the ends of the floor temperature sensor to expose the wires for ease of installation. Insert the floor temperature sensor wires into terminals C and D. Note that the floor temperature sensor wires have no polarity and can be interchanged between C and D terminals. Tighten the screws to secure the wires. The power, heating cable, and floor temperature sensor connections are now complete. Replace the thermostat faceplate and tighten the screw at the bottom of the unit.
Note: Two DITRA-HEAT-E-HK heating cables can be connected and controlled by a single DITRA-HEAT-E-R thermostat if the total current is less than 15 amps. The heating cable leads must be wired in parallel according to applicable electrical and building codes. Multiple DITRA-HEAT-E-HK heating cables over 15 amps cannot be connected to a single DITRA-HEAT-E-R thermostat. Additional DITRA-HEAT-E-R thermostats must be used or the DITRA-HEAT-E-R thermostat may be combined with the DITRA-HEAT-E-RR power modules.
Comparison Chart
Non-Programmable Thermostat
Used to control the DITRA-HEAT-E-HK heating cables
Smart Thermostat
Third-party integration with popular voice and home assistants
Touchscreen Thermostat
3.5” intuitive touchscreen display
Other Features
Digital display with backlit screen
Other Features
Multiple energy-saving functions
Other Features
Ability to track and log power consumption
About Us Always One Step Ahead of the Times!
At Schlüter-Systems, we pride ourselves on being pioneers in the tile assembly industry. Founded in 1966 by Werner Schlüter, we continue to meet the evolving demands of the industry by developing practical and effective solutions for tile installation challenges. Today, Schlüter-Systems’ has evolved from a modest idea into a company with over 40 product lines recognized and utilized in various countries around the world, maintaining our commitment to innovation, quality, and service.
How do I connect the Schluter-DITRA-HEAT-E-HK Heating Cables to DITRA-HEAT-E thermostats?
For instructions on connecting the DITRA-HEAT-E thermostats, please reference the Schluter-DITRA-HEAT Thermostat User’s Guides or the Schluter-DITRA-HEAT Installation Handbook.
Can more than one DITRA-HEAT-E-HK heating cable be connected to the Schluter-DITRA-HEAT-E Thermostats?
Multiple DITRA-HEAT-E-HK cables can be controlled by one DITRA-HEAT-E thermostat if the total current is under 15 amps. The junction box must meet regional electrical codes and account for pigtails and thermostat space.
Simple Operation – Equipped with an easy on/off switch and backlit digital display for straightforward temperature control.
Versatile – Designed for both 120V and 240V Ditra-Heat-E-HK heating cables, suitable for different power needs and room sizes.
Sleek Design – Offers a compact and sleek design in bright white, seamlessly integrating into any room aesthetic.
Safety First – Includes a class A Ground Fault Circuit Interrupter (GFCI) with indicator light, ensures safety in your bathroom or kitchen installations.
Easy Installation – Crafted for quick installation within a single gang, deep electrical box, or a double gang electrical box with a single gang mud ring.
There are no reviews yet.